Get Point Industrial Pte Ltd

TEL : 65-62541170 FAX : 65-62541156 Email: getpoint@singnet.com.sg

Thermo Electric Wire & Cable

TEL : 65-62541170

 

Overall Shielded 300 Volt
Flame retardant PVC insulation over conductors twisted into pairs. Pairs are cabled together with an overall shield and PVC overall jacket. Construction is UL listed PLTC or ITC rated 300 volt. Available with thermocouple extension or copper conductors. FEP, TPE or CPE insulations and jackets are also available. Overall Shielded 300 Volt


Polyvinyl Chloride
221F (105C)

 

 

Individual and Overall Shielded 300 Volt
Flame retardant PVC insulation over conductors twisted into shielded pairs. Pairs are cabled together with an overall shield and PVC jacket. Construction is UL listed PLTC or ITC rated 300 volt. Available with thermocouple extension or copper conductors. FEP, TPE or CPE insulations and jackets are also available. Individual and Overall Shielded 300 Volt


Polyvinyl Chloride
221F (105C)

 

 

Served Wire Armor 300 Volt
Flame retardant PVC insulation over conductors twisted into shielded pairs. Pairs are cabled together with an overall shield and PVC inner jacket. Galvanized steel served wire armor is helically applied and an overall PVC jacket completes the construction. UL listed PLTC or ITC rated 300 volt. This construction features excellent mechanical protection and tensile strength as well as exceptional resistance to rodent and mechanical abuse. Available with thermocouple extension or copper conductors. Overall shield only construction is also available. FEP, TPE, and CPE insulations and jackets are available. Served Wire Armor 300 Volt


Polyvinyl Chloride
221F (105C)

 

 

Metal Bond Tape 300 Volt
Flame retardant PVC insulation over conductors twisted into shielded pairs. Pairs are cabled together with an overall shield and inner PVC jacket. A continuously bonded aluminum composite tape is applied longitudinally with an overall CPE jacket bonded to the tape. This construction offers excellent moisture and chemical resistance as well as exceptional mechanical strength and is UL listed PLTC or ITC rated 300 volt. Available with thermocouple extension or copper conductors. Overall shield only construction is also available. Metal Bond Tape 300 Volt


Polyvinyl Chloride
221F (105C)

 

 

Instrumentation Cable 600 Volt
Flame retardant PVC and Nylon insulation over conductors twisted into shielded pairs. Pairs are cabled together with an overall shield and PVC jacket. UL listed TC rated 600 volt. Available with thermocouple or copper conductors. Overall shield only construction is also available. TPE and CPE insulations and jackets are available. Instrumentation Cable 600 Volt


Polyvinyl Chloride/Nylon
194F (90C)

 

 

Control Cable 600 Volt
Flame retardant PVC and Nylon insulation over conductors all cabled together under a PVC jacket. UL listed TC rated 600 volt. Cable available shielded and non-shielded. TPE and CPE insulations and jackets are available. Control Cable 600 Volt


Polyvinyl Chloride/Nylon
194F (90C)